318 research outputs found

    Anal infections with concomitant Chlamydia trachomatis genotypes among men who have sex with men in Amsterdam, the Netherlands.

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Lymphogranuloma venereum (LGV) proctitis is caused by <it>Chlamydia trachomatis </it>(Ct) genotype L and is endemic among men who have sex with men (MSM) in western society. Genotype L infections need to be distinguished from non-LGV (genotypes A-K) Ct infections since they require prolonged antibiotic treatment. For this purpose, an in-house developed <it>pmpH </it>based LGV polymerase chain reaction (PCR) test is used at the Amsterdam STI outpatient clinic. We investigated retrospectively the anal Ct genotype distribution, and the frequency of concomitant genotype infections in MSM infected with LGV and non-LGV Ct infections. To detect concomitant Ct genotype infections, the <it>pmpH </it>LGV PCR and genoTyping Reverse Hybridization Assay (Ct-DT RHA) were used.</p> <p>Methods</p> <p>A total of 201 Ct positive rectal swabs from MSM were selected, which were previously diagnosed as either LGV (n = 99) or non-LGV Ct infection (n = 102) according to the algorithm of Ct detection by the commercially available Aptima Combo 2 assay followed by an in-house <it>pmpH </it>LGV PCR. The samples were retested with the commercially available Ct-DT RHA, which differentiates between 14 major genotypes and is able to detect concomitant Ct genotypes.</p> <p>Results</p> <p>Excellent genotyping agreement was observed between the Ct-DT RHA and the <it>pmpH </it>LGV PCR (Kappa = 0.900, 95%CI = 0.845-0.955, McNemar's p = 1.000). A concomitant non-LGV genotype was detected in 6/99 (6.1%) LGV samples. No additional LGV infections were observed with the Ct-DT RHA among the non-LGV Ct group. In the non-LGV group genotype G/Ga (34.3%) was seen most frequent, followed by genotype D/Da (22.5%) and genotype J (13.7%). All LGV infections were caused by genotype L2.</p> <p>Conclusions</p> <p>Concomitant non-LGV genotypes do not lead to missed LGV proctitis diagnosis. The <it>pmpH </it>LGV PCR displayed excellent agreement with the commercially available Ct-DT genotyping RHA test. The genotypes G/Ga, D/Da and J were the most frequent non-LGV Ct strains in MSM.</p

    Rituximab in early systemic sclerosis

    Get PDF
    Objectives (1) Hypothesis testing of the potency of rituximab (RTX) in preventing fibrotic complications and (2) assessing acceptability and feasibility of RTX in early systemic sclerosis (SSc). Methods A small, 24-month, randomised, double-blind, placebo-controlled, single-centre trial in patients with SSc diagnosed <2 years was conducted. Patients received RTX or placebo infusions at t=0, t=15 days and t=6 months. Patients were clinically evaluated every 3 months, with lung function tests and high-resolution CT every other visit. Skin biopsies were taken at baseline and month 3. Immunophenotyping of peripheral blood mononuclear cells was performed at every visit, except at months 9 and 18. Adverse events, course of skin and pulmonary involvement and B cell populations in skin and peripheral blood were evaluated. Results In total 16, patients (rituximab n=8, placebo n=8) were included. Twelve patients had diffuse cutaneous SS

    Emission spectra and intrinsic optical bistability in a two-level medium

    Full text link
    Scattering of resonant radiation in a dense two-level medium is studied theoretically with account for local field effects and renormalization of the resonance frequency. Intrinsic optical bistability is viewed as switching between different spectral patterns of fluorescent light controlled by the incident field strength. Response spectra are calculated analytically for the entire hysteresis loop of atomic excitation. The equations to describe the non-linear interaction of an atomic ensemble with light are derived from the Bogolubov-Born-Green-Kirkwood-Yvon hierarchy for reduced single particle density matrices of atoms and quantized field modes and their correlation operators. The spectral power of scattered light with separated coherent and incoherent constituents is obtained straightforwardly within the hierarchy. The formula obtained for emission spectra can be used to distinguish between possible mechanisms suggested to produce intrinsic bistability.Comment: 18 pages, 5 figure

    LDIP cooperates with SEIPIN and LDAP to facilitate lipid droplet biogenesis in Arabidopsis

    Get PDF
    Abstract Cytoplasmic lipid droplets (LDs) are evolutionarily conserved organelles that store neutral lipids and play critical roles in plant growth, development, and stress responses. However, the molecular mechanisms underlying their biogenesis at the endoplasmic reticulum (ER) remain obscure. Here we show that a recently identified protein termed LD-associated protein [LDAP]-interacting protein (LDIP) works together with both endoplasmic reticulum-localized SEIPIN and the LD-coat protein LDAP to facilitate LD formation in Arabidopsis thaliana. Heterologous expression in insect cells demonstrated that LDAP is required for the targeting of LDIP to the LD surface, and both proteins are required for the production of normal numbers and sizes of LDs in plant cells. LDIP also interacts with SEIPIN via a conserved hydrophobic helix in SEIPIN and LDIP functions together with SEIPIN to modulate LD numbers and sizes in plants. Further, the co-expression of both proteins is required to restore normal LD production in SEIPIN-deficient yeast cells. These data, combined with the analogous function of LDIP to a mammalian protein called LD Assembly Factor 1, are discussed in the context of a new model for LD biogenesis in plant cells with evolutionary connections to LD biogenesis in other eukaryotes

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    The exposure of the hybrid detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The "hybrid" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic
    corecore